Jenn Air Cooktop W10197059B User Manual

30" (76.2 CM) AND 36" (91.4 CM) ELECTRIC  
DOWNDRAFT COOKTOP INSTALLATION INSTRUCTIONS  
INSTRUCTIONS D’INSTALLATION DE LA TABLE DE  
CUISSON ÉLECTRIQUE AVEC ASPIRATION PAR LE BAS DE  
30" (76,2 CM) ET 36" (91,4 CM)  
Table of Contents/Table des matières  
COOKTOP SAFETY..............................................................................2  
SÉCURITÉ DE LA TABLE DE CUISSON....................................... 13  
INSTALLATION REQUIREMENTS ......................................................3  
Tools and Parts..................................................................................3  
Location Requirements......................................................................3  
Venting Requirements .......................................................................5  
Venting Methods................................................................................6  
Electrical Requirements ....................................................................7  
INSTALLATION INSTRUCTIONS ........................................................8  
Prepare Cooktop................................................................................8  
Install Foam Strip...............................................................................8  
Rotate Blower - Optional...................................................................8  
Install Cooktop.................................................................................10  
Make Electrical Connection.............................................................10  
Complete Installation.......................................................................11  
EXIGENCES D'INSTALLATION...................................................... 14  
Outillage et pièces........................................................................ 14  
Exigences d'emplacement........................................................... 14  
Exigences concernant l'évacuation ............................................. 16  
Méthodes d'évacuation................................................................ 17  
Spécifications électriques ............................................................ 18  
INSTRUCTIONS D’INSTALLATION............................................... 19  
Préparation de la table de cuisson............................................... 19  
Installation de la bande de mousse ............................................. 19  
Rotation du ventilateur - Facultative ............................................ 20  
Installation de la table de cuisson................................................ 21  
Raccordement électrique............................................................. 21  
Achever l'installation..................................................................... 22  
IMPORTANT:  
Save for local electrical inspector's use.  
IMPORTANT :  
À conserver pour consultation par l'inspecteur local des installations électriques.  
W10197059B  
 
INSTALLATION REQUIREMENTS  
Tools and Parts  
Location Requirements  
Gather the required tools and parts before starting installation.  
Read and follow the instructions provided with any tools listed  
here.  
Tools needed  
IMPORTANT: Observe all governing codes and ordinances. When  
installing cooktop, use minimum dimensions given.  
To eliminate the risk of burns or fire by reaching over the  
heated surface units, cabinet storage space located above the  
surface units should be avoided. If cabinet storage is to be  
provided, the risk can be reduced by installing a range hood  
that projects horizontally a minimum of 5" (12.7 cm) beyond  
the bottom of the cabinets.  
Tape measure  
Flat-blade screwdriver  
Phillips head screwdriver  
Drill  
Marker or pencil  
Pliers  
¼" drill bit  
Use the countertop opening dimensions that are given with  
these Installation Instructions. Given dimensions are minimum  
clearances and provide 0" (0 cm) clearance.  
Jigsaw  
Level  
Ratchet with ³⁄₈"socket  
Grounded electrical supply is required. See “Electrical  
Requirements” section.  
6" socket extension  
If cabinet has drawers, drawers will need to be removed and  
drawer fronts installed on front of cabinet.  
Parts supplied  
Vent grille  
IMPORTANT: An under-counter built-in oven cannot be installed  
under this product.  
Pre-filter  
Parts needed  
Product Dimensions  
A UL listed or CSA approved strain relief for ⁷⁄₈" (2.2 cm)  
knockout.  
30" (76.2 cm) Cooktop - for standard and electric models  
A UL listed or CSA approved conduit connector for  
¹⁄₂" (1.3 cm) trade-size metal-clad conduit  
UL listed wire connectors  
Metal ducting  
Jenn-Air wall cap  
Jenn-Air® 6" (15.2 cm) Round Surface Wall Cap Damper  
Order Part Number A406  
Jenn-Air® 3¼" x 10" (8.3 x 25.4 cm) Surface Wall Cap Damper  
Order Part Number A403  
C
B
To order, see the “Assistance or Service” section of the Use  
and Care Guide.  
A
Vent clamps  
A. Model/serial rating plate location  
B. 20⁹⁄₁₆" (52.3 cm)  
C. 22" (55.9 cm)  
Check local codes. Check existing electrical supply. See  
“Electrical Requirements” section.  
It is recommended that all electrical connections be made by a  
licensed, qualified electrical installer.  
3
 
A
Cabinet Dimensions  
B
H
A
D
F
G
B
C
C
E
D
L
F
G
E
A. 29³⁄₄" (75.6 cm)  
B. 12¹⁄₂" (31.8 cm) centerline of product to edge of burner box  
C. 12¹⁄₂" (31.8 cm)  
D. 28³⁄₈" (73.3 cm)  
H
I
E. 12¹⁄₂" (31.8 cm)  
F. 2" (5.1 cm) recommended minimum cabinet to motor clearance  
J
K
G. 16³⁄₈" (41.6 cm)  
H. 4⁵⁄₈" (11.8 cm)  
36" (91.4 cm) Cooktop - for standard and electric models  
A. 30" (76.2 cm) on 30" (76.2 cm) models  
36" (91.4 cm) on 36" (91.4 cm) models  
B. Combustible area above countertop (shown by dashed box above)  
C. 30" (76.2 cm) minimum clearance between top of cooktop platform  
and bottom of uncovered wood or metal cabinet (24" [61 cm]  
minimum clearance if bottom of wood or metal cabinet is covered  
by not less than ¹⁄₄" [0.6 cm] flame retardant millboard covered with  
not less than No. 28 MSG sheet steel, 0.015" [0.04 cm] stainless  
steel, or 0.024" [0.06 cm] aluminum or 0.020" [0.05 cm] copper)  
D. 13" (33 cm) recommended upper cabinet depth  
E. 2" (5.1 cm)  
F. 21¹⁄₈" (73.4 cm)  
C
A
B
G. 18" (45.7 cm) minimum clearance from upper cabinet to countertop  
within minimum horizontal clearances to cooktop  
H. Junction box or outlet; 12" (30.5 cm) minimum from bottom of  
countertop  
I. Junction box or outlet; 10" (25.4 cm) from right-hand side of  
cabinet  
A. Model/serial rating plate location  
B. 20⁹⁄₁₆" (52.3 cm)  
C. 22" (55.9 cm)  
J. 28⁷⁄₈" (73.4 cm) on 30" (76.2 cm) models  
34½" (87.6 cm) on 36" (91.4 cm) models  
K. 2½" (6.4 cm) minimum distance to nearest left and right side  
combustible surface above cooktop  
A
B
L. 1½" (3.8 cm) minimum clearance between back wall and  
countertop  
H
G
NOTES: After making the countertop cutout, some installations  
may require notching down the base cabinet side walls to clear  
the cooktop base. To avoid this modification, use a base cabinet  
with sidewalls wider than the cutout.  
C
F
A minimum side clearance of 6" (15.2 cm) is recommended  
between side of cooktop and side wall for maximum  
ventilation performance.  
E
D
A minimum clearance of 2" (5.1 cm) is recommended between  
the motor/blower and cabinet for proper cooling. A  
6" (15.2 cm) clearance is recommended for servicing access.  
A. 35¹¹⁄₃₂" (89.8 cm)  
B. 12⁷⁄₈" (32.8 cm) centerline of product to edge of burner box  
C. 12⁷⁄₈" (32.8 cm)  
D. 34¹⁄₈" (87.3 cm)  
E. 12¹⁄₂" (31.8 cm)  
F. 2" (5.1 cm) recommended minimum cabinet to motor clearance  
G. 16³⁄₈" (41.6 cm)  
H. 4⁵⁄₈" (11.8 cm)  
4
 
For Best Performance:  
Cutout Dimensions  
Use 26-gauge minimum galvanized or 25-gauge minimum  
aluminum metal vent. Poor quality pipe fittings can reduce  
airflow. Flexible metal vent is not recommended.  
B
A
C
NOTE: Local codes may require a heavier gauge material.  
Metal duct may be reduced to 30-gauge galvanized steel or  
26-gauge aluminized steel if allowed by local codes. This  
reduction is based on information in the International  
Residential Codes Section M1601.1 (2006 edition).  
D
E
Do not install 2 elbows together.  
F
Use no more than three 90° elbows.  
H
If an elbow is used, install it as far away as possible from the  
hood’s vent motor exhaust opening.  
I
Make sure there is a minimum of 18" (45.7 cm) of straight vent  
between the elbows if more than one elbow is used.  
J
G
Elbows too close together can cause excess turbulence that  
reduces airflow.  
Do not use a 5" (12.7 cm) elbow in a 6" (15.2 cm) or 3¹⁄₄" x 10"  
(8.3 x 25.4 cm) system.  
A. 28⁷⁄₈" (73.4 cm) maximum on 30" (76.2 cm) models  
34½" (87.6 cm) maximum on 36" (91.4 cm) models  
B. 21¹⁄₈" (53.7 cm)maximum on both 30" (76.2 cm) and 36" (91.4 cm)  
Do not reduce to a 5" (12.7 cm) system after using  
6" (15.2 cm) or 3¹⁄₄" x 10" (8.3 x 25.4 cm) fittings.  
Avoid forming handmade crimps. Handmade crimps may  
restrict airflow.  
Use a Jenn-Air® vent cap for proper performance. If an  
alternate wall or roof cap is used, be certain the cap size is not  
reduced and that it has a backdraft damper.  
models  
C. 8⁵⁄₈" (21.9 cm) on 30" (76.2 cm) models  
15⁷⁄₁₆" (39.2 cm) on 36" (91.4 cm) models  
D. 6⁵⁄₁₆" (16.0 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models  
E. 2" (5.1 cm) minimum space to front edge of cooktop  
F. Floor exhaust option  
G. 6¹⁄₈" (15.6 cm) for 6" vent system  
H. 8⁵⁄₈" (21.9 cm) on 30" (76.2 cm) models  
15⁷⁄₁₆" (39.2 cm) on 36" (91.4 cm) models  
Use vent clamps to seal all joints in the vent system.  
Use caulking to seal exterior wall or roof opening around the  
cap.  
I. 16" (40.6 cm) on both 30" (76.2 cm) and 36" (91.4 cm) models  
J. Wall exhaust option  
The length of vent system and number of elbows should be kept  
to a minimum to provide efficient performance.  
The maximum equivalent length of the vent system is  
60 ft (18.3 m). For altitudes above 4,500 ft (1272 m), reduce  
recommended vent run by 20% for best performance.  
Venting Requirements  
IMPORTANT: This cooktop must be exhausted outdoors unless  
using the Jenn-Air® Duct Free Filter Accessory Kit. See “Venting  
Methods” section.  
Cold Weather Installations  
An additional backdraft damper should be installed to minimize  
backward cold air flow and a thermal break installed to minimize  
conduction of outside temperatures as part of the vent system.  
The damper should be on the cold air side of the thermal break.  
Do not terminate the vent system in an attic or other enclosed  
area.  
Use a Jenn-Air® vent cap.  
Makeup Air  
Vent system must terminate to the outside.  
Local building codes may require the use of makeup air systems  
when using ventilation systems greater than specified CFM of air  
movement. The specified CFM varies from locale to locale.  
Consult your HVAC professional for specific requirements in your  
area.  
Use only a 6" (15.2 cm) round metal vent. Rigid metal vent is  
recommended. For best performance, do not use plastic or  
metal foil vent.  
Before making cutouts, make sure there is proper clearance  
within the wall or floor for the exhaust vent.  
Do not cut a joist or stud unless absolutely necessary. If a joist  
or stud must be cut, then a supporting frame must be  
constructed.  
The size of the vent should be uniform.  
The vent system must have a damper. If roof or wall cap has a  
damper, do not use damper supplied with the range hood.  
Use vent clamps to seal all joints in the vent system.  
Use caulking to seal exterior wall or roof opening around the  
cap.  
Determine which venting method is best for your application.  
5
 
Venting Methods  
Common venting methods are shown for a counter-mounted  
downdraft cooktop. The cooktop may be vented through the wall  
or floor.  
Concrete Slab Installations - Exhaust Through Wall  
B
Option 1 - Roof Venting  
Option 2 - Wall Venting  
A
D
E
B
F
C
N
G
B
H
M
I
K
L
J
A. Wall cap  
B. 6" (15.2 cm) round metal vent  
C. 16" (40.6 cm) maximum  
A
D. 6" (15.2 cm) round PVC sewer pipe  
E. 6" (15.2 cm) round metal vent  
F. 6" (15.2 cm) round PVC coupling  
G. Concrete slab  
A
H. 6" (15.2 cm) round PVC sewer pipe  
I. 6" (15.2 cm) round 90° PVC sewer pipe elbow  
J. Tightly pack gravel or sand completely around pipe.  
K. 30 ft (9.1 m) max.  
A. Roof cap  
B. 6" (15.2 cm) round roof  
venting  
A. 6" (15.2 cm) round wall  
venting  
B. Wall cap  
L. 6" (15.2 cm) round 90° PVC sewer pipe elbow  
M. 6" (15.2 cm) round PVC coupling  
N. 12" (30.5 cm) minimum  
Option 3 - Venting Between  
Floor Joist  
Option 4 - Venting behind  
Cabinet Kick Plate  
Jenn-Air® Duct Free Filter Accessory Kit  
(For model numbers JED3430, JED3536, JED4430, JED4536,  
JGD3430 and JGD3536)  
On select downdraft models, the Jenn-Air® Duct Free Filter  
Accessory Kit Part Number JDA7000WX is now available. The  
Jenn-Air® Duct Free Filter Accessory Kit is ideal for both new  
construction and kitchen renovation projects because it provides  
an easy alternative to the installation of metal ducting and venting  
in the downdraft system outside the home. The kit includes all  
required hardware, one filter and complete installation  
instructions. For more information on the Jenn-Air® Duct Free Filter  
Accessory Kit, contact your Jenn-Air® dealer or call  
B
A
B
A
1-800-JENNAIR (1-800-536-6247).  
A. Wall cap  
A. Wall cap  
B. 6" (15.2 cm) round wall  
venting  
B. 6" (15.2 cm) round wall  
venting  
6